Product description
Data traveling cables are now almost an integral part of every elevator shaft electrical installation. Data traveling cables ensure the data communication of the cabin's electronic elements with the switchboard.
The FLi-2YS(ST)(C)TH 1xCAT7 cable is directly in the halogen-free design, which is used in elevator installations where it is needed, such as evacuation elevators, fire-fighting elevators and elevators where it is determined by the fire department's requirement.
The cable's outer insulating sheath contains a special low-smoke, halogen-free, flame-retardant thermoplastic compound.
Technical parameters:
Number of pairs: | 4 |
Bearing element: | galvanized steel rope 1,8 mm |
Test Voltage: | 1000 V (DC, 1min) |
Ethernet cable: | CAT7 |
Maximum free hanging length: | 50 m |
Maximum travel speed: | 4 m/s |
Operating temperature range: | -15 °C až 60 °C |
Minimum bending radius: | 10 x cable height |
Dimensions (height x width): | 8 mm x 17,6 mm |
Standards: | Similar as EN 50214 |
Electrical data (nominal):
F | Attenuation | NEXT | ACR | Return loss | PS-NEXT | PS-ACR | ACFR | PS-ACFR |
(MHz) | (db / 100m) | (dB) | (dB / 100m) | (dB) | (dB) | (dB / 100m) | (dB / 100m) | (dB / 100m) |
1 | 3 | 100 | 97 | - | 97 | 94 | 90 | 87 |
4 | 6 | 100 | 95 | 27 | 97 | 92 | 90 | 87 |
10 | 8 | 100 | 92 | 28 | 97 | 89 | 84 | 81 |
16 | 10 | 100 | 90 | 28 | 97 | 87 | 80 | 77 |
20 | 11 | 97 | 86 | 28 | 97 | 83 | 80 | 77 |
31 | 14 | 95 | 81 | 28 | 92 | 78 | 75 | 72 |
63 | 20 | 95 | 75 | 28 | 92 | 72 | 73 | 70 |
100 | 26 | 95 | 69 | 28 | 92 | 66 | 66 | 63 |
155 | 32 | 94 | 62 | 26 | 91 | 59 | 62 | 59 |
200 | 37 | 93 | 56 | 25 | 90 | 53 | 56 | 53 |
250 | 41 | 93 | 52 | 25 | 90 | 79 | 53 | 50 |
300 | 47 | 92 | 45 | 23 | 89 | 72 | 45 | 42 |
600 | 68 | 90 | 22 | 20 | 87 | 19 | 39 | 36 |
750 | 77 | 58 | 8 | 18 | 82 | 5 | - | - |
900 | 88 | 83 | -5 | 17 | 80 | -8 | - | - |
1000 | 95 | 80 | -15 | 17 | 77 | -18 | - | - |